Model Number : 1.2V 200Ah
Certification : CB CE UN38.3 MSDS
Place of Origin : China
MOQ : 1000PCS
Payment Terms : L/C,T/T,Western Union
Delivery Time : 35 working days
Packaging Details : Industrial Pakcage
Battery Type : Nicd Battery Pack Ups
Capacity : 200Ah
Voltage : 1.2V
Dimension : L:105 W: 165 H:345
Weight : 10.5kg
Discharge Cut-off Voltage : 1.0V
Self-Discharge Rate : 10-15% per month
Guarantee : Three Years
Features
Wide Temperature Operation: Performs from -40°C to +50°C
High Reliability: Proven technology for critical applications
Overcharge Tolerance: Withstands continuous overcharge
Deep Discharge Recovery: Full recovery from complete discharge
Low Maintenance: Minimal watering requirements
Long Service Life: 15-20 years design life
High Rate Capability: Supports high current discharges
Specification
| Normal Voltage | 1.2V |
| Capacity | 200Ah |
| Weight | With Electrolyte: 10.0kg/22.0lbs Without Electrolyte: 7.8kg/17.2lbs |
| Dimensions | L:105/4.1 W:165/6.5 H:345/13.6 (mm/inch) |
| Operating Teerature Range | -20°C to + 60°C(-4°F to +140°F) |
| Cycle Life | ≥2000 cycles (to 80% capacity) |
| Design Life | 15-20 years |
| Self-Discharge Rate | 10-15% per month |
| Standard Charge Current | 0.1C (20A) for 7-8 hours |
| Max Discharge Current | 5C (1000A) for 30 seconds |
| Discharge Cut-off Voltage | 1.0V |
| Internal Resistance | ≤0.1mΩ |

UPS Systems: Uninterruptible power supplies for critical infrastructure
Telecommunications: Base station backup power
Security Systems: Alarm and access control systems
Medical Equipment: Emergency medical device backup
Industrial Control Systems: Process control backup power
Railway Signaling: Signaling system backup power
Charging Precautions
Maintain float voltage at 1.40-1.45V per cell at 20°C
Perform equalization charges monthly at 1.50-1.55V per cell
Monitor temperature during charging - reduce voltage at higher temperatures
Never exceed 1.65V per cell under any conditions
Electrolyte Handling
Use only distilled or demineralized water for topping up
Maintain electrolyte level above plates but below maximum mark
Never add acid to electrolyte - only add water
Clean any electrolyte spills immediately with bicarbonate solution
Discharging Precautions
Limit maximum discharge current to 5C (1000A) for 30 seconds maximum
Monitor cell temperatures during high-rate discharges
Allow cooling between high-current discharge cycles
Storage & Handling
Keep away from direct sunlight and heat sources
Store upright to prevent electrolyte leakage
Keep terminals protected and insulated when not in use
Implement earthquake protection in seismic zones
Transportation
Secure properly to prevent movement during transit
Comply with IATA DGR for air transport
Follow ADR/RID/IMDG regulations for ground/sea transport
Package as UN 2795, Battery, wet, filled with alkali
|
|